Changes in version 3.4.4 - Fix issue #349: dropChromPeaks fails if no retention time adjustment process history is present. Changes in version 3.4.2 - Fix issue #325: matchedFilter peak detection on data containing empty spectra. Changes in version 3.4.1 - Small fix in the xcms vignette (issue #327). Changes in version 3.3.6 - Add type = "polygon" to highlightChromPeaks allowing to fill the actual signal area of identified chromatographic peaks. Changes in version 3.3.5 - Performance enhancement of the chromPeakSpectra and featureSpectra functions. Changes in version 3.3.4 - Add featureChromatograms to extract ion chromatograms for each feature. - Add hasFilledChromPeaks function. - Add argument skipFilled to the featureSummary function. Changes in version 3.3.3 - Add chromPeakSpectra and featureSpectra functions to extract MS2 spectra for chromatographic peaks and features, respectively (issue #321). - Fix profMat to handle also data files with empty spectra (issue #312). - Add argument ylim to plotAdjustedRtime (issue #314). - Add imputeRowMin and imputeRowMinRand, two simple missing value imputation helper functions. - Fix additional problem mentioned in issue #301 with obiwarp retention time correction if some spectra have m/z values of `NA`. - Fix issue #300 avoiding chromatographic peaks with rtmin > rtmax. - Fixes for issues #291, #296. - Add parameter 'missing' to diffreport allowing to replace NA with arbitrary numbers. - Add exportMetaboAnalyst function to export the feature matrix in MetaboAnalyst format. - Add parameter missing to featureValues allowing to specify how to handle/ report missing values. - The chromPeaks matrix has now rownames to uniquely identify chromatographic peaks in an experiment. Chromatographic peak IDs start with "CP" followed by a number. Changes in version 3.3.2 - Add writeMSData method for XCMSnExp allowing to write mzML/mzXML files with adjusted retention times (issue #294). - Fix profEIC call for single-scan-peak (pull request #287 from @trljcl). - Fix centWave avoiding that the same peak is reported multiple times if fitgauss = TRUE is used (issue #284). - featureSummary reports also RSD (relative standard deviations) of features across samples (issue #286). - Add parameters fixedMz and fixedRt to FillChromPeaksParam that allow to increase the features' m/z and rt widths by a constant factor. - Add option "sum" to featureValues' method parameter allowing to sum the intensities of peaks that are assigned to the same feature in a file/sample. Changes in version 3.3.1 - Add overlappingFeatures function to identify overlapping or close features. - Add support for type = "apex_within" for featureDefinitions. - Fix a bug in fillChromPeaks that would return the integrated signal being Inf. - Fix for issue #267: error in fillChromPeaks when the retention time of the peaks are outside of the retention time range of certain files. - New featureSummary function to calculate basic feature summaries (number of samples in which peaks were found etc). - Parameter 'type' added to plotChromPeakDensity and 'whichPeaks' to highlightChromPeaks. Both parameters are passed to the 'type' argument of chromPeaks. - Parameter 'type' in chromPeaks gets additional option "apex_within" to return chromatographic peaks that have their apex within the defined rt and/or m/z range. - Add functions rla and rowRla to calculate RLA (relative log abundances). - Add peaksWithMatchedFilter to perform peak detection in chromatographic (MRM/SRM) data (issues #277 and #278). - Add peaksWithCentWave to perform centWave peak detection in chromatographic (MRM/SRM) data (issue #279). - Add findChromPeaks,Chromatogram methods for CentWaveParam and MatchedFilterParam (issue #280). Changes in version 3.1.3 BUG FIXES: - Fix misplaced parenthesis in the check for multiple spectra in findChromPeaks,OnDiskMSnExp,MSWParam. Thanks to @RonanDaly (PR #276). - Update link to correct metlin page in diffreport result (issue #204). Changes in version 3.1.2 NEW FEATURES - Add filterFeatureDefinitions function. BUG FIXES: - Fix #273: better error message in case not a single feature could be defined by groupChromPeaks. Changes in version 3.1.1 NEW FEATURES - Reading raw files using xcmsSet or xcmsRaw uses now the automatic file type detection feature from mzR. - c function to concatenate XCMSnExp objects. - groupnames method for XCMSnExp objects (issue #250). BUG FIXES: - Fix #237: findPeaks.MSW was not throwing an error if applied to multi-spectrum MS file. - Fix #249: quantile call in adjustRtime PeakGroups without na.rm = TRUE. - Fix #259 Changes in version 2.99.10 BUG FIXES: - Fix #230: Failing vignettes on Windows. Changes in version 2.99.9 USER VISIBLE CHANGES: - Chromatographic peak detection uses adjusted retention times on an aligned XCMSnExp object (issue #213, #208). - New parameter msLevel for processHistory,XCMSnExp. - New parameter keepAdjustedRtime for filterMsLevel,XCMSnExp, dropChromPeaks, XCMSnExp and dropFeatureDefinitions,XCMSnExp. - Add parameter msLevel to chromatogram,XCMSnExp method (issue #205). - Obiwarp alignment is now performed on one MS level and adjustment is applied to all MS levels (issue #214). - Add function plotMsData to plot intensity against retention time and m/z against retention time for a MS slice in one sample. - Add argument msLevel = 1L to extractMsData method (issue #223). - New applyAdjustedRtime function to consolidate the alignment results, i.e. replace the raw retention times in the XCMSnExp with the adjusted retention times. - [,XCMSnExp method gains argument keepAdjustedRtime to allow keeping adjusted retention times in the sub-setting. - Implement spectrapply,XCMSnExp to ensure returned results use adjusted retention times (if present). - [[,XCMSnExp method returns a Spectrum object with adjusted retention time, if the XCMSnExp contains adjusted retention times. - Argument 'sampleGroups' is mandatory for 'PeakDensityParam' (issue #228). BUG FIXES: - Fix #191: Excessive memory use in fillPeaks. - Fix #220: peaks matrix is missing column "sample" if no peaks were found in the first sample. - Fix #222: findChromPeaks does not return an XCMSnExp object filtered to a single MS level despite peak detection is performed on a single level. - Fix problem in plotMsData causing wrong colors to be used to label the data points. Changes in version 2.99.8 BUG FIXES: - Replace xcmsMSn Rnw with Rmd vignette to fix Windows build errors. Changes in version 2.99.7 BUG FIXES: - Fix #201: Warnings: 'readMSData2' is deprecated, thanks to L. Gatto. - Merge with BioC git after transition Changes in version 2.99.6 NEW FEATURES: - calibrate,XCMSnExp method that allows to calibrate chromatographic peaks. USER VISIBLE CHANGES: - Export phenoDataFromPaths function (issue $195). - Add arguments mz and rt to featureDefinitions method allowing to extract features within the specified ranges. - Increase n for the density function call in group density-based correspondence by 2. - Replace xcmsDirect.Rnw with rmarkdown-based vignette using the new user interface. BUG FIXES: - issue #196: removed the unnecessary requirement for same-dimension profile matrices in adjustRtime,XCMSnExp,ObiwarpParam. - issue #194: fixes in retcor.obiwarp: 1) subset raw data if scanrange != NULL. 2) if the mz range of the two files to be aligned differ, expand them correctly. Depending on the profStep and the mz values/ranges the matrices were not expanded correctly. - Potential problems in the plotChromPeakDensity function. Changes in version 2.99.5 USER VISIBLE CHANGES: - Re-enable sleep parameter in findPeaks.centWave and findPeaks.matchedFilter. Changes in version 2.99.4 NEW FEATURES: - Add plotChromPeaks function to plot the definition (rt and mz range) of detected chromatographic peaks of one file into the mz-rt plane. - Add plotChromPeakImage function to plot the number of detected peaks along the retention time axis per file as an image plot. USER VISIBLE CHANGES: - Move Chromatogram class and functionality to the MSnbase package - Add argument msLevel to the findChromPeaks method to allow (chromatographic) peak detection also on MS level > 1. BUG FIXES: - Polarity information was not read from mzXML files (issue #192). Changes in version 2.99.3 BUG FIXES: - issue #188: determine file type from file content if file ending not known. Changes in version 2.99.2 BUG FIXES: - issue #181: problem when isCentroided,Spectrum method returns NA because of too few peaks in a spectrum. Fixed by checking in such cases all spectra in the file. - issue #184: add parameter sleep to do_groupChromPeaks_density function to be backwards compatible with the old group.density code. Changes in version 2.99.1 NEW FEATURES: - extractMsData to extract raw MS data as a data.frame (issue #120). BUG FIXES: - issue #175: an error is now thrown if no peak group was identified for peak group retention time correction. - issue #178: scanrange was collapsed when the adjusted range was reported (pull request by Jan Stanstrup). - issue #180: error when both parameters method and smooth are provided in the retcor method. Changes in version 2.99.0 NEW FEATURES: - plotChromatogram and highlightChromPeaks functions. - plotChromPeakDensity function. - clean method for Chromatogram classes. USER VISIBLE CHANGES: - Change default for ppm parameter in chromPeaks method to 0. - extractChromatograms supports extraction of multiple rt and mz ranges. - New parameter missing for extractChromatograms allowing to specify the intensity value to be used for rts for which no signal is available within the mz range. - extractChromatograms returns Chromatograms of length equal to the number of scans within the specified rt range, even if no signals are measured (intensity values are NA). Changes in version 1.53.1 BUG FIXES: - Increase parameter n for the density call in the peak density correspondence method. This enables to separate neighboring peaks using small n (issue #161). Thanks to Jan Stanstrup. Changes in version 1.51.11 NEW FEATURES: - Parameter "filled" for featureValues (issue #157). - Parameters "rt" and "mz" in chromPeaks method allowing to extract chromatographic peaks from the specified ranges (issue #156). BUG FIXES: - Fixed possible memory problem in obiwarp (issue #159). - Update getPeaks to use non-deprecated API (issue #163). Changes in version 1.51.10 NEW FEATURES: - filterRt for Chromatogram class (issue #142). - adjustRtimePeakGroups function (issue #147). - adjustRtime,XCMSnExp,PeakGroupsParam and do_adjustRtime_peakGroups support use of pre-defined matrix to perform alignment (issue #153). - plotAdjustedRtime to visualize alignment results (issue #141). USER VISIBLE CHANGES: - featureDefinitions and featureValues return DataFrame and matrix with rownames corresponding to arbitrary feature IDs (issue #148). - New peakGroupsMatrix slot for PeakGroupsParam class (issue #153). BUG FIXES: - Issue #146: ensure adjusted retention times returned by the peakGroups method to be in the same order than the raw retention times. Changes in version 1.51.9 NEW FEATURES: - fillChromPeaks, dropFilledChromPeaks methods and FillChromPeaksParam class. - featureValues method. USER VISIBLE CHANGES: - Extended new_functionality vignette. - Change default backend for reading mzML files to pwiz. BUG FIXES: - Issue #135: fix peak signal integration for centWave. - Issue #139: problem with expand.mz and expand.rt in fillPeaks.chrom. - Issue #137: Error in findChromPeaks if no peaks are found. Changes in version 1.51.8 NEW FEATURES: - Add Chromatogram class and extractChromatograms method. BUG FIXES: - Issue #118: failing unit test on Windows build machine. - Issue #133: error with c() and xcmsSet without peaks. - Issue #134: xcmsSet constructor endless loop. Changes in version 1.51.7 USER VISIBLE CHANGES: - Major renaming of methods and classes to follow the naming convention: - chromatographic peak (chromPeak): the peaks identified in rt dimension. - feature: mz-rt feature, being the grouped chromatographic peaks within and across samples. BUG FIXES: - Issue #127: failing unit test on Windows build machine. Changes in version 1.51.6 NEW FEATURES: - groupFeatures and adjustRtime methods for XCMSnExp objects. - New Param classes for groupFeatures and adjustRtime analysis methods: FeatureDensityParam, MzClustParam, NearestFeaturesParam, FeatureGroupsParam and ObiwarpParam. BUG FIXES: - Issue #124 (filterRt,XCMSnExp returned empty object). Changes in version 1.51.5 NEW FEATURES: - MsFeatureData and XCMSnExp objects. - features, features<-, adjustedRtime, adjustedRtime<-, featureGroups, featureGroups<-, hasAlignedFeatures, hasAdjustedRtime and hasDetectedFeatures methods. - dropFeatures, dropFeatureGroups and dropAdjustedRtime methods. - filterMz, filterRt, filterFile etc implemented. - mz, intensity and rtime methods for XCMSnExp allowing to return values grouped by sample. BUG FIXES: - Issue #99 (rtrange outside of retention time range in getEIC,xcmsSet). - Issue #101 (xcmsRaw function returns NULL if mslevel = 1 is specified). - Issue #102 (centWave returns empty matrix if scales not OK). Thanks to J. Stanstrup. - Issue #91 (warning instead of error if no peaks in ROI). Thanks to J. Stanstrup. Changes in version 1.51.4 BUG FIXES: - added deepCopy to avoid corrupting the original object, thanks to J. Stanstrup, closes #93 Changes in version 1.51.3 NEW FEATURES: - binYonX binning function. - imputeLinInterpol function providing linear interpolation of missing values. - breaks_on_binSize and breaks_on_nBins functions to calculate breaks defining bins. - New vignette "new_functionality.Rmd" describing new and modified functionality in xcms. - Add do_detectFeatures_matchedFilter function. - Add do_detectFeatures_centWave function. - Add do_detectFeatures_centWaveWithPredIsoROIs function and unit test. - Implement a new data import function. - Add do_detectFeatures_MSW function and unit test. - Argument stopOnError in xcmsSet function that allows to perform feature detection on all files without stopping on errors. - Method showError for xcmsSet objects that list all errors during feature detection (if stopOnError = FALSE in the xcmsSet function). - [ method to subset xcmsRaw objects by scans. - profMat method to extract/create the profile matrix from/for an xcmsRaw. - Add new detectFeatures methods for MSnExp and OnDiskMSnExp objects from the MSnbase package. - Add new CentWaveParam, MatchedFilterParam, MassifquantParam, MSWParam and CentWavePredIsoParam parameter class to perform method dispatch in the detectFeatures method. - retcor.obiwarp uses the new binning methods for profile matrix generation. - scanrange,xcmsRaw reports always a scanrange of 1 and length(object@scantime). - scanrange,xcmsSet reports the scanrange eventually specified by the user in the xcmsSet function. - Fixed bug in rawMat (issue #58). - Fix issue #60: findPeaks.massifquant always returns a xcmsPeaks object. Changes in version 1.51.2 USER VISIBLE CHANGES: - As suggested by Jan Stanstrup, do not error if a centWave ROI contains no data, closes #90 Changes in version 1.51.1 BUG FIXES: - Fix incorrrect indexing getEIC function reported by Will Edmands, closes #92 Changes in version 1.49.7 BUG FIXES: - Fix documentation warnings. Changes in version 1.49.6 USER VISIBLE CHANGES: - Peak Picking function findPeaks.centWaveWithPredictedIsotopeROIs() and findPeaks.addPredictedIsotopeFeatures(), which allow more sensitive detection of isotope features. Changes in version 1.49.5 USER VISIBLE CHANGES: - Some documentation updates. - Preparation for a new binning function Changes in version 1.49.4 BUG FIXES: - Fix getXcmsRaw that would prevent retention time correction to be applied (issue #44 reported by Aleksandr). Changes in version 1.49.3 NEW FEATURE: - updateObject method for xcmsSet. USER VISIBLE CHANGES: - xcms uses now BiocParallel for parallel processing. All other parallel processing functions have been deprecated. BUG FIXES: - Added missing package imports. - Fix bug in fillPeaksChromPar referencing a non-existing variables i and object. - Fix bug in group.nearest: variable scoreList was mis-spelled (coreList). - Remove all DUP = FALSE from the .C calls as they are ignored anyways. OTHER CHANGES - Re-organization of class, function and method definitions in R-files. - Use roxygen2 to manage the DESCRIPTION's collate field. Changes in version 1.49.2 NEW FEATURE: - Initial support for exporint mzTab format. Since Changes are still to be expected, xcms:::writeMzTab() is not yet exported. Changes in version 1.49.1 NEW FEATURE: - The raw CDF/mzXML/mzData/mzML is assumed to have scans sorted by m/z. Instead of throwing an "m/z sort assumption violated !" error, the data is re-read and on-demand sorted by m/z. Changes in version 1.47.3 - Disable parallel processing in unit tests causing a timeout on BioC build machines Changes in version 1.47.2 BUG FIXES - Fix problem in getEIC on xcmsSet objects reported by Alan Smith in issue #7 and add a RUnit test case to test for this (test.issue7 in runit.getEIC.R). - Changed some unnecessary warnings into messages. Changes in version 1.47.2 USER VISIBLE CHANGES: - Disabled parallel processing in unit tests * migrate dependencies from ncdf -> ncdf4 Changes in version 1.45.7 USER VISIBLE CHANGES: - Disabled Rmpi support and usage on Windows Changes in version 1.45.6 NEW FEATURE: - J. Rainer implemented a [ method that allows to subset an xcmsSet. BUG FIXES: - Fixed a problem in split.xcmsSet that did not split the phenoData properly. Added some details to the documentation of xcmsSet-class. Changes in version 1.45.5 USER VISIBLE CHANGES: - The sampclass method for xcmsSet will now return the content of the column "class" from the data.frame in the phenoData slot, or if not present, the interaction of all factors (columns) of that data.frame. - The sampclass<- method replaces the content of the "class" column in the phenoData data.frame. If a data.frame is submitted, the interaction of its columns is calculated and stored into the "class" column. BUG FIXES: - Fixed a bug that resulted in a cryptic error message when no input files are available to the xcmsSet function. Changes in version 1.45.4 BUG FIXES: - Fixed a bug in the levelplot method for xcmsSet. Changes in version 1.45.3 NEW FEATURE: - xcmsSet now allows phenoData to be an AnnotatedDataFrame. - new slots for xcmsRaw: - mslevel: store the mslevel parameter submitted to xcmsRaw. - scanrange: store the scanrange parameter submitted to xcmsRaw. - new slots for xcmsSet: - mslevel: stores the mslevel argument from the xcmsSet method. - scanrange: to keep track of the scanrange argument of the xcmsSet method. - new methods for xcmsRaw: - levelplot: similar to the image method, plots m/z vs RT with color coded intensities. - mslevel: returns the value for the .mslevel slot. For downstream compatibility, this method returns NULL if the object does not have the same named slot. - profinfo: same functionality as the profinfo method for xcmsSet. - scanrange: returns the value for the scanrange slot. For downstream compatibility, this method returns NULL if the object does not have the same named slot. - new methods for xcmsSet: - getXcmsRaw: returns a xcmsRaw object for one or more files in the xcmsSet, eventually applying retention time correction etc. - levelplot: similar to the image method, plots m/z vs RT with color coded intensities. Allows in addition to highlight identified peaks. - mslevel: returns the value for the mslevel slot. For downstream compatibility, this method returns NULL if the object does not have the same named slot. - profMethod: same functionality as the profMethod method of xcmsRaw. - profStep: same functionality as the profStep method of xcmsRaw. - scanrange: returns the value for the scanrange slot. For downstream compatibility, this method returns NULL if the object does not have the same named slot. USER VISIBLE CHANGES: - show method for xcmsSet updated to display also informations about the mslevel and scanrange. - Elaborated some documentation entries. - rtrange and mzrange for xcmsRaw method plotEIC use by default the full RT and m/z range. - Added arguments "lty" and "add" to plotEIC method for xcmsRaw. - getEIC without specifying mzrange returns the ion chromatogram for the full m/z range (i.e. the base peak chromatogram). BUG FIXES: - Checking if phenoData is a data.frame or AnnotatedDataFrame and throw an error otherwise. - xcmsSet getEIC method for water Lock mass corrected files for a subset of files did not evaluate whether the specified files were corrected. Changes in version 1.45.2 BUG FIXES: o The xcms split() function now accepts factors that are shorter than the number of samples in the xcmsSet, following more closely the standard split() behaviour Changes in version 1.45.1 NEW FEATURE: o plotrt now allows col to be a vector of color definition, same as the plots for retcor methods. o Added $ method to access phenoData columns in a eSet/ExpressionSet like manner. o Allow to use the "parallel" package for parallel processing of the functions xcmsSet and fillPeaks.chrom. o Thanks to J. Rainer! Changes in version 1.43.3 BUG FIXES: o Give a more verbose error message when file not found Changes in version 1.43.2 BUG FIXES: o Use ProtGenerics, adapted xcms peaks() Changes in version 1.43.1 NEW FEATURE: o function plotQC() for plotting various QC plots on RT and m/z Changes in version 1.41.1 BUG FIXES: o fix sampclass generation from phenoData if some combinations of factors don't exist o disable parallel code in manpages to avoid issues on BioC windows build farm machines Changes in version 1.39.6 USER VISIBLE CHANGES: o Massifquant reports the maximum intensity for each isotope trace (peak). This is useful for interactive parameter optimization. BUG FIXES: o Major memory reduction in parallel fillPeaks() thanks to Jan Stanstrup. Now using an environment to mirror gvals to each list item in the very large argList. Changes in version 1.39.4 BUG FIXES: o Fixed write.cdf(), which had an intensity offset of +1, added a unit test Changes in version 1.39.3 BUG FIXES: o New R-devel check unload better. Lingering ramp code removed, import from mzR. Cleaned up other errors in package check. Changes in version 1.39.1 BUG FIXES: o Updated doubleMatrix c code to allow for larger profile matrixes REQUIRED CHANGES o Moved inst/doc to vignettes Changes in version 1.37.6 NEW FEATURE: o Introducing write.mzQuantML(xcmsSet) to export the peak list and grouped matrix to the PSI format mzQuantML (see http://www.psidev.info/mzquantml) USER VISIBLE CHANGES: o Add Brigham Young University to LICENSE file for copyright purposes. o Add copyright information display when running findPeaks.massifquant() within xcmsRaw.R o Clean and update documentation for findPeaks.massifquant-methods.Rd BUG FIXES: o Remove unused parameters in findKalmanROIs() within xcmsRaw.R Changes in version 1.37.5 BUG FIXES o fixed bug in retcor.obiwarp where the scanrange of the first sample would be checked instead of the center sample Changes in version 1.37.4 BUG FIXES o Skip t-test in diffreport() if one class has less than 2 samples. Changes in version 1.37.3 BUG FIXES o fixed bug in patternVsRowScore (group.nearest) that was introduced by the modifications in rev 65169 and caused features to be aligned that were far outside the given m/z and retention time windows. Changes in version 1.37.1 BUG FIXES o fixed fillPeaks, which 1) dropped non-standard columns and 2) failed if nothing to do, based on patches by Tony Larson. Changes in version 1.37.1 NEW FEATURES: o Introducing msn2xcmsRaw, to allow findPeaks() on MS2 and MSn data Changes in version 1.35.7 BUG FIXES o fixed indexing bug in group.nearest, which under certain circumstances caused all peaks in the first sample to be ignored (reported by Tony Larson) Changes in version 1.35.6 BUG FIXES o Obiwarp retention time alignment error-ed if scanrange was used as a parameter setting during xcmsSet/peak detection The method now tries to automatically find the set scanrange and uses this range for alignment. Changes in version 1.35.4 NEW FEATURES: o Introducing parallel fillPeaks USER VISIBLE CHANGES o Replace snow requirement with minimum R version 2.14.0 Changes in version 1.35.3 BUG FIXES o if group.density was used with very low minfrac settings (< 0.5) it did not return all feature groups, but only those that include features from at least 50% of samples in a group. This limitation was removed. Changes in version 1.35.2 UPDATED FEATURES: o Behind the scenes xcms now uses the xcmsSource class to read raw data. This allows e.g. to write a class that pulls raw data from e.g. a database BUG FIXES o massifquant: simplified logic structure of Tracker::claimDataIdx resolved failure on new test case. o massifquant: reporting features data structure compatible with multiple sample comparison within XCMS. Changes in version 1.35.1 UPDATED FEATURES: o The mzData export is now much faster and uses less memory Changes in version 1.33.16 USER VISIBLE CHANGES o diffreport and plotEIC have a new parameter mzdec, with is the number of decimal places of the m/z values in the EIC plot title Changes in version 1.33.16 UPDATED FEATURES: Lock mass gap filler now works with netCDF lock mass function file to find the exact times of the scans and works with the newer Waters MS instruments. Changes in version 1.33.15 BUG FIXES o scanrage is now honoured in xcmsSet, also when in parallel mode Changes in version 1.33.14 BUG FIXES o scanrage is now honoured in xcmsRaw, and consequently also in xcmsSet(matchedFilter), where previously it was ignored. Changes in version 1.33.13 BUG FIXES o write.cdf() has been fixed to write files AMDIS can read Changes in version 1.33.12 BUG FIXES o write.mzData adds Polarity to the file if available Changes in version 1.33.11 USER VISIBLE CHANGES o centWave uses a new method to estimate local noise which improves detection of closely spaced peaks NEW FEATURES o placeholder BUG FIXES o group.mzClust was failing when result had one peak For more details and all changes before May 2012 please see the (now discontinued) CHANGELOG in the source package (inst/ folder). CHANGED BEHAVIOUR since Version 1.32: Other Changes since Version 1.32: * improved mzData writing, now includes MSn spectra and less verbose. * improved netCDF writing, but not yet good enough for AMDIS CHANGED BEHAVIOUR since Version 1.14: * centWave may report a smaller set of peaks, due to a small bug in the ROI algorithm some features with mass deviation > ppm were retained. Other Changes since Version 1.14: * New method for grouping: an algorithm inspired by mzMine group(method="nearest") has been implemented. It is slower than group(method="density"). It can individually group close-eluting peaks of very similar mass * New method for retention time correction: The retcor(method="obiwarp") algorithm operates on the raw data, and thus allows to correct runs without well-behaving peak groups, or without peak picking at all. * fillPeaks(method="MSW") is now also available for direct infusion spectra. The findPeaks(method="MSW") now returns several intensities, and correctly reports mzmin and mzmax for peaks. * centWave now uses dynamic memory allocation, needs much less memory, and these BUF related errors should be a thing of the past. * centWave gains an optional argument "noise", which is useful for data that was centroided without any intensity threshold, centroids with intensity < "noise" are omitted from ROI detection * the fillPeaks() methods now remember which was an observed, and which was a "filled" peak. * For direct infusion spectra diffreport() now shows the raw peak shapes, and also indicated "real" and "filled" peaks. * xcmsRaw can now filter for positive/negative spectra, if the file includes both polarities. xcmsSet() can pass the polarity to contain positive/negative peaks only.