title: Using Bioconductor with High Throughput Assays
output:
  BiocStyle::html_document
date: 24 April 2018
vignette: >
  %\VignetteIndexEntry{Using Bioconductor with High Throughput Assays}
  %\VignetteEngine{knitr::rmarkdown}
author:
- name: Bioconductor Maintainer
  affiliation: Roswell Park Cancer Institute, Elm and Carlton St, Buffalo, NY 14263
  email: maintainer@bioconductor.org
abstract: >
  Bioconductor includes packages for analysis of diverse areas of
  high-throughput assays such as flow cytometry, quantitative real-time PCR,
  mass spectrometry, proteomics and other cell-based data.
---

# Version Info
```{r, echo=FALSE, results="hide", warning=FALSE}
suppressPackageStartupMessages({
library('highthroughputassays')
})
```
<p>
**R version**: `r R.version.string`
<br />
**Bioconductor version**: `r BiocManager::version()`
<br />
**Package version**: `r packageVersion("highthroughputassays")`
</p>

# Sample Workflow

The following psuedo-code illustrates a typical R / Bioconductor
session. It makes use of the flow cytometry packages to load, transform and
visualize the flow data and gate certain populations in the dataset. 

The workflow loads the `flowCore`, `flowStats` and `flowWorkspace` packages and its
dependencies.  It loads the ITN data with 15 samples, each of which includes,
in addition to FSC and SSC, 5 fluorescence channels: CD3, CD4, CD8, CD69 and
HLADR. 

```{r echo=FALSE, results="hide", warning=FALSE}
suppressPackageStartupMessages(library(flowCore))
suppressPackageStartupMessages(library(flowStats))
suppressPackageStartupMessages(library(flowWorkspace))
suppressPackageStartupMessages(library(ggcyto))
suppressPackageStartupMessages(library(scales))
```

```{r}
## Load packages
library(flowCore)
library(flowStats)
library(flowWorkspace)
library(ggcyto)
library(scales)

## Load data
data(ITN)
ITN
```

First, we need to transform all the fluorescence channels. Using a `GatingSet`
object can help to keep track of our progress.

```{r}
## Create a workflow instance and transform data using asinh
gs <- GatingSet(ITN)
trans.obj <- trans_new("myAsinh", transform=asinh, inverse=sinh)
tl <- transformerList(colnames(ITN)[3:7], trans.obj)
gs <- transform(gs, tl)

```

Next we use the `lymphGate` function to find the T-cells in the CD3/SSC
projection.
    
```{r}
## Identify T-cells population
lg <- lymphGate(gs_cyto_data(gs), channels=c("CD3", "SSC"),
                preselection="CD4", filterId="TCells",
                scale=2.5)
gs_pop_add(gs, lg)
recompute(gs)

ggcyto(gs, aes(x = CD3, y = SSC)) + geom_hex(bins = 32) + geom_gate("TCells")

```

    
A typical workflow for flow cytometry data analysis in Bioconductor flow
packages include data transformation, normalization, filtering, manual gating,
semi-automatic gating and automatic clustering if desired. Details can be
found in [flowWorkFlow.pdf](flowWorkFlow.pdf) or the vignettes of the
[flow cytometry packages](#diverse-assays-resources).

<p class="back_to_top">[ <a href="#top">Back to top</a> ]</p>

# Installation and Use

Follow [installation instructions](/install/) to start using these
packages.  To install the `flowCore` package and all of its
dependencies, evaluate the commands

```{r eval=FALSE}
if (!"BiocManager" %in% rownames(installed.packages()))
     install.packages("BiocManager")
BiocManager::install("flowCore")
```

Package installation is required only once per R installation. View a
full list of
[available packages](/packages/release/bioc/).

To use the `flowCore` package, evaluate the command

```{r eval=FALSE}
library("flowCore")
```

This instruction is required once in each R session.

<p class="back_to_top">[ <a href="#top">Back to top</a> ]</p>

# Exploring Package Content

Packages have extensive help pages, and include vignettes highlighting
common use cases. The help pages and vignettes are available from
within R. After loading a package, use syntax like

    help(package="flowCore")
    ?read.FCS

to obtain an overview of help on the `flowCore` package, and the
`read.FCS` function, and

```{r eval=FALSE}
browseVignettes(package="flowCore")
```

to view vignettes (providing a more comprehensive introduction to
package functionality) in the `flowCore` package. Use

```{r eval=FALSE}
help.start()
```
to open a web page containing comprehensive help resources.

<p class="back_to_top">[ <a href="#top">Back to top</a> ]</p>

# Diverse Assays Resources

The following provide a brief overview of packages useful for analysis
of high-throughput assays. More comprehensive workflows can be found
in documentation (available from [package
descriptions](/packages/release/bioc/))
and in Bioconductor [publications](/help/publications/).

## Flow Cytometry ##

These packages use standard FCS files, including infrastructure,
utilities, visualization and semi-autogating methods for the
analysis of flow cytometry data.

[flowCore](/packages/release/bioc/html/flowCore.html),
[flowViz](/packages/release/bioc/html/flowViz.html),
[flowQ](/packages/release/bioc/html/flowQ.html),
[flowStats](/packages/release/bioc/html/flowStats.html),
[flowUtils](/packages/release/bioc/html/flowUtils.html),
[flowFP](/packages/release/bioc/html/flowFP.html),
[flowTrans](/packages/release/bioc/html/flowTrans.html),

Algorithms for clustering flow cytometry data are found in these packages:

[flowClust](/packages/release/bioc/html/flowClust.html),
[flowMeans](/packages/release/bioc/html/flowMeans.html),
[flowMerge](/packages/release/bioc/html/flowMerge.html),
[SamSPECTRAL](/packages/release/bioc/html/SamSPECTRAL.html)

A typical workflow using the packages `flowCore`, `flowViz`, `flowQ` and
`flowStats` is described in detail in [flowWorkFlow.pdf](flowWorkFlow.pdf).
The data files used in the workflow can be downloaded from
[here](dataFiles.tar).

## Cell-based Assays ##

These packages provide data structures and algorithms for cell-based
high-throughput screens (HTS).

[cellHTS2](/packages/release/bioc/html/cellHTS2.html),
[RNAither](/packages/release/bioc/html/RNAither.html)

This package supports the xCELLigence system which contains a series of
real-time cell analyzer (RTCA).

[RTCA](/packages/release/bioc/html/RTCA.html)

## High-throughput qPCR Assays ##

These package provide algorithm for the analysis of cycle threshold
(Ct) from quantitative real-time PCR data.

[HTqPCR](/packages/release/bioc/html/HTqPCR.html),
[ddCt](/packages/release/bioc/html/ddCt.html),
[qpcrNorm](/packages/release/bioc/html/qpcrNorm.html)

## Mass Spectrometry and Proteomics data ##

These packages provide framework for processing, visualization, and
statistical analysis of mass spectral and proteomics data.

[clippda](/packages/release/bioc/html/clippda.html),
[MassArray](/packages/release/bioc/html/MassArray.html),
[MassSpecWavelet](/packages/release/bioc/html/MassSpecWavelet.html),
[PROcess](/packages/release/bioc/html/PROcess.html),
[flagme](/packages/release/bioc/html/flagme.html),
[xcms](/packages/release/bioc/html/xcms.html)

## Imaging Based Assays ##

These packages provide infrastructure for image-based phenotyping and automation of other image-related tasks:

[EBImage](/packages/release/bioc/html/EBImage.html),
[imageHTS](/packages/release/bioc/html/imagHTS.html)

<p class="back_to_top">[ <a href="#top">Back to top</a> ]</p>

```{r}
sessionInfo()
```

<p class="back_to_top">[ <a href="#top">Back to top</a> ]</p>